Overview
The 22A-B4P5N104 is a PowerFlex 4 Series compact AC drive that supports multiple operating modes, including sensorless vector control via built-in keypad, external control signal or RS485 communication, dynamic response time < 1ms, integrated LED display and fixed keypad.
Parameter
| Parameter | 22A‑B4P5N104 | 22A‑A4P5N104 | 22A‑B8P0N104 | 25A‑B5P0N104 (Replacement) |
|---|---|---|---|---|
| Product Line | PowerFlex 4 | PowerFlex 4 | PowerFlex 4 | PowerFlex 523 (Replacement for PF4) |
| Input Phase/Voltage | 3‑Phase, 180‑264V AC | 1‑Phase, 180‑264V AC | 3‑Phase, 180‑264V AC | 3‑Phase, 180‑264V AC |
| Output Power (kW/HP) | 0.75/1.0 | 0.75/1.0 | 1.5/2.0 | 0.75/1.0 |
| Output Current | 4.5 A | 4.5 A | 8.0 A | 5.0 A |
| Frame Size | Frame A | Frame A | Frame A | Frame A |
| Control Mode | Sensorless Vector | Sensorless Vector | Sensorless Vector | Sensorless Vector, V/Hz |
| Built‑in Brake IGBT | Included | Included | Included | Included |
| Communication | RS485 | RS485 | RS485 | RS485, optional EtherNet/IP |
| Enclosure Rating | IP20 (Open) | IP20 (Open) | IP20 (Open) | IP20 (Open) |
| User Interface | Fixed Keypad + LED | Fixed Keypad + LED | Fixed Keypad + LED | Fixed Keypad + LED |
| Lifecycle Status | Discontinued (2025‑06‑30) | Discontinued | Discontinued | Active |
FAQ:
1.22A-B4P5N104 What is the function of the built-in braking IGBT? Is an external braking resistor required?
- Braking IGBT: conducts regenerative current to prevent bus overvoltage and ensure smooth deceleration/stop.
- External braking resistor: not required for light load and long deceleration time (≥10-20 seconds); external braking resistor for heavy load, rapid deceleration/frequent start and stop (connect to P+/PB terminal, match resistance power).
2.What control methods and operating modes does 22A-B4P5N104 support?
Control method:
- Sensorless Vector Control (SVC)
- V/Hz control
operating mode:
- local keyboard control
- External analog control (0–10V/4–20mA)
- External digital/RS485 Modbus control
- composite control
3.22A-B4P5N104 Is the wiring and programming fully compatible with the discontinued replacement model 25A-B5P0N104?
- Wiring: The main circuit (power supply, motor, braking resistor) terminals are compatible and can be directly reused; digital/analog I/O and communication terminals have the same definition, no need to change the wiring.
- Program: Basic control parameters can be imported, but new functions (such as EtherNet/IP) need to be adapted, and some parameters need to be fine-tuned, so they are not completely compatible without modification.