SIMOREG DC Master Inverter, with microprocessor for single-quadrant drives B6C connection Input: 400V 3AC, 25A controllable: Field rectifier D485/30 MRE-GEE6S22 output: 485 V DC, 30 A Output US-Rating: 485 V DC, 25A Field-input. 400V-output. 325 V, 5 A G94=Communication module PROFIBUS CBP2 inserted at Slot D G95=Communication module PROFIBUS CBP2 inserted at Slot E K01=Adapter module for Slot D and E K11=Local BusAdapter for electronics box LBA
| Delivery information | |
| Export Control Regulations | ECCN : EAR99 / AL : N |
| Standard lead time ex-works | 20 Day/Days |
| Net Weight (kg) | 11,350 Kg |
| Package size unit of measure | Not available |
| Quantity Unit | 1 Piece |
| Packaging Quantity | 1 |
FAQ:
1. What types of motors are suitable for 6RA7018-6DS22-0?
6RA7018-6DS22-0 is only suitable for DC motors:
- Separately excited DC motor (most commonly used)
- Shunt, series and compound excited DC motors
2.6RA7018-6DS22-0 Common fault codes and their meanings?
| Code | Fault Description |
|---|---|
| F001 | Electronics power supply fault |
| F004 | Armature supply phase failure / phase voltage fault |
| F005 | Excitation circuit fault |
| F006 | Under voltage |
| F007 | Over voltage |
| F008 | Input frequency too low |
| F009 | Input frequency too high |
| F022 | External fault (e.g. fast fuse blown) |
| F030 | Armature overcurrent / pulse inhibit |
| F031 | Speed controller monitoring |
| F038 | Overspeed |
| F040 | Fault not reset |
| F042 | Tachometer / encoder feedback fault |
| F048 | Encoder measurement channel fault |
| F050 | Automatic optimization failed |
| F061 | Thyristor detection fault |
| F062 | Internal memory fault |
3.6RA7018-6DS22-0 What are the fault reset methods?
- Reset the operation panel: Press the P key → find r001 or fault interface → press the L or reset key.
- Power off reset: power off the device, wait 1~2 minutes and then power on again.
- Terminal reset: Give a short-circuit on-off signal through the external reset terminal (such as terminal 14, 15, according to the wiring).
- Parameter reset: After troubleshooting, reset parameter P085=1.
- Communication reset: Send reset command through communication such as Profibus/USS.