Overview
The Bosch Rexroth Servo Drive R911298373 (HCS02.1E-W0054-A-03-NNNN) – Three-phase AC 200-500 V, 24 VDC compatible with motors: 1.5-11 kW (without reactor) / Up to 16 kW (with external reactor) DC bus power: 7 kW (without reactor) / 10 kW (with reactor) Built-in axial flow fan IP20 Supports multiple encoder interfaces With control unit slot
Specification
| Item | Specification |
|---|---|
| Material No. | R911298373 |
| Model Number | HCS02.1E-W0054-A-03-NNNN |
| Manufacturer | Bosch Rexroth |
| Product Series | IndraDrive C |
| Product Type | Compact Single-Axis Servo Drive |
| Main Power Supply | 3-phase AC 200~500 V ±10%, 50/60 Hz |
| Control Power Supply | 24 VDC ±20%, Power Consumption approx. 23 W |
| Continuous Output Current | 20.6 A |
| Peak Output Current | 54 A (2.5x overload capacity) |
| Compatible Motor Power | 1.5~11 kW (without reactor); up to 16 kW (with external reactor) |
| Output Frequency | 0~1600 Hz |
| Switching Frequency | 4/12/16 kHz selectable |
| DC Bus Power | 7 kW (without reactor); 10 kW (with reactor) |
| Short Circuit Withstand Current (SCCR) | 42 kA (rms) |
| Dimensions (W×H×D) | 105 mm × 352 mm × 252 mm |
| Weight | 6.7 kg |
| Cooling Method | Built-in axial fan forced air cooling (230 V) |
| Ingress Protection | IP20 |
| Pollution Degree | 2 |
| Operating Ambient Temperature | 0~+40 ℃ |
| Storage Temperature | -20~+80 ℃ |
| Control Modes | Position/Speed/Torque closed-loop, servo & variable frequency operation supported |
| Encoder Interface | Compatible with multiple encoder types (Resolver, EnDat, Hiperface, etc.) |
| Communication Expansion | Control unit slot available, supports PROFIBUS, PROFINET, EtherCAT and other fieldbus cards |
| Standard Safety Function | STO (Safe Torque Off), other safety functions expandable |
| I/O Configuration | Multi-channel digital input/output, analog input/output |
FAQ
1.What are the control power supply voltage and power consumption parameters for R911298373 (HCS02.1E-W0054-A-03-NNNN)?
The
- Control power supply voltage: DC 24 V ±20% (allowable range: 19.2 – 28.8 V)
- Control power supply power consumption: approximately 23 W
2.What are the product’s protection level and pollution level respectively? (R911298373 (HCS02.1E-W0054-A-03-NNNN))
Supported. The Protection level: IP20, Pollution level: 2
3.What is the maximum power that can be adapted after installing the external reactor on R911298373 (HCS02.1E-W0054-A-03-NNNN)?
The
- After installing the external power choke, the maximum power that the motor can be adapted to is: 16 kW.
- Without the choke: The maximum adaptable power is 11-12 kW.
- With the external choke: The maximum adaptable power is 16 kW.
- Continuous power of the DC bus: 7 kW (without choke) / 10 kW (with choke)
4.What are the available switching frequencies for the power module R911298373 (HCS02.1E-W0054-A-03-NNNN)?
The
Total 4 settings:
- 4 kHz → Maximum output frequency: 0 – 400 Hz
- 8 kHz → Maximum output frequency: 0 – 800 Hz
- 12 kHz → Maximum output frequency: 0 – 1200 Hz
- 16 kHz → Maximum output frequency: 0 – 1600 Hz
Looking for Original New R911298373(HCS02.1E‑W0054‑A‑03‑NNNN) 200~500 VAC
We supply this R911298373 (HCS02.1E-W0054-A-03-NNNN) mainly to system integrators and maintenance teams for replacement and retrofit projects.
Contact US to get a good prices now !