Overview
The MELSEC iQ-F FX5U-64MT/DS is powered by DC24V, with 32-point input X0 to X37 + 32-point output Y0 to Y37, fixed drain transistor output, integrated analog quantity (no expansion module required), 64K Flash memory, RJ45 Ethernet port Terminal RS485 interface 35mm DIN rail snap-on installation, or screw panel fixation 220mm wide × 90mm high × 86mm deep M3 detachable screw terminal block
Specification
| Item | Specification |
|---|---|
| Model | FX5U-64MT/DS |
| Product Series | Mitsubishi MELSEC iQ-F FX5U Series |
| Total Built-in I/O Points | 64 points (32 Input / 32 Output) |
| Main Power Supply Type | DC24V |
| Allowable Main Voltage Range | DC 19.2V ~ 28.8V |
| Rated Power Consumption Current | Approx. 0.75A (Excluding external sensor loads) |
| Built-in Auxiliary Sensor Power | DC24V for input sensors |
| Momentary Power Failure Resistance | Max. 10ms continuous operation |
| Input Terminals | X0 ~ X37, 32 points |
| Input Signal Specification | DC24V, photo-coupler isolated |
| Input Wiring Mode | Sink(NPN) / Source(PNP) switchable via S/S terminal |
| Single Input Current | 3.5mA per point |
| Standard Input Response Time | 1ms; minimum adjustable 0.1ms for high-speed mode |
| Output Type | Transistor Sink (Fixed NPN) |
| Output Terminals | Y0 ~ Y37, 32 points |
| Output Load Voltage Range | DC 5V ~ 30V |
| Single Point Max Output Current | 0.5A per point |
| Max Current Per 4-point Common Group | ≤2A |
| Pulse Axis Response Speed (Y0/Y1/Y2/Y3) | 5μs |
| General Output Response Speed | 0.2ms |
| Built-in Analog Input Channels | 2 channels (0~10V / 4~20mA, 12-bit resolution) |
| Built-in Analog Output Channels | 1 channel (0~10V / 4~20mA, 12-bit resolution) |
| Program Memory Capacity | 64K steps Flash memory |
| Program Backup Requirement | No battery required for program storage |
| Basic LD Instruction Execution Speed | 34ns per instruction |
| Supported Programming Languages | LD, ST, SFC, FBD, multi-task execution, FB function block |
| Total Built-in High-Speed Counter Axes | 8 axes |
| Max Frequency of 6 General Counter Axes | 200kHz (Single-phase / AB orthogonal encoder) |
| Max Frequency of 2 Low-Speed Counter Axes | 10kHz |
| Independent Pulse Output Axes | 4 axes (Y0,Y1,Y2,Y3) |
| Max Pulse Frequency Per Axis | 200kHz |
| Pulse Output Modes | Pulse + Direction / CW & CCW double pulse |
| Built-in Motion Functions | Homing, electronic cam, multi-axis synchronization, linear interpolation |
| Onboard Standard Communication Ports | 1×RJ45 Ethernet, 1×Terminal RS485 |
| Supported Communication Protocols | SLMP, MODBUS TCP, MODBUS-RTU, N:N Network, FTP |
| Expansion Slot | Left FX5U-BD communication expansion slot |
| SD Card Slot | For program backup, data logging, firmware upgrade, batch copy |
| Max Local I/O (CPU + Local Expansion Modules) | 256 points |
| Max Total I/O with CC-Link Remote I/O | 512 points |
| Mounting Method | Standard 35mm DIN rail mounting, optional screw panel mounting |
| Overall Dimension | W220mm × H90mm × D86mm |
| Terminal Screw Specification | M3 removable terminal block |
| Operating Ambient Temperature | 0℃ ~ +55℃ |
| Storage Temperature | -20℃ ~ +70℃ |
| Protection Class | IP20 (For cabinet internal installation only) |
| Global Certifications | UL/cUL, CE, RoHS, DNV, ABS, LR, KC |
FAQ
1.FX5U-64MT/DS The total number of IO points on the main body, with input and output being how many points respectively?
The The total input/output ports of the main body are 64. The input ports are 32 (from X0 to X37), and the output ports are 32 (from Y0 to Y37).
2.Does the FX5U-64MT/DS input terminal support switching wiring for shunt-type and source-type sensors?
Supported. The
- Support: The input terminals of FX5U-64MT/DS can freely switch between leakage-type and source-type sensor wiring through the S/S common terminal:
- When S/S is connected to the positive pole of DC24V → leakage-type input, suitable for NPN sensors;
- When S/S is connected to the negative pole of 0V → source-type input, suitable for PNP sensors.
3.How many independent servo pulse output axes does the FX5U-64MT/DS have?
The 4th path, corresponding terminals Y0, Y1, Y2, Y3
4.What are the protection level, standard installation method and overall size of the FX5U-64MT/DS?
The
- Protection level: IP20. It can only be installed inside a sealed control cabinet. It cannot be used directly exposed in open-air, humid, or dusty environments.
- Standard installation method:
- Mainstream: 35mm standard DIN rail snap-in installation
- Alternative: M4 screws directly fixed on the back panel of the control cabinet
- Overall dimensions: Width 220mm × Height 90mm × Depth 83mm
Looking for Original New Mitsubishi FX5U-64MT/DS PLC CPU main nit Compact IP20
We supply this FX5U-64MT/DS mainly to system integrators and maintenance teams for replacement and retrofit projects.
Contact US to get a good prices now !


Reviews