Overview
The SICK Dx50 Series High-Resolution Distance Measurement Technology Mid-range Laser Ranging Sensor with Red Laser 658nm, Laser Class 1, 1-channel PNP Digital Switch Output, 1-channel Multi-function Input LCD Screen, 2 Status LED Indicators, M12 5-pin Connector, Zinc Alloy Molded Housing, Optical Window PMMA Plastic, IP65
Specificatio
| Item | Specification |
|---|---|
| Part Number | DT50-P1123 |
| Order No. | 1047118 |
| Brand | SICK |
| Product Type | Time-of-Flight Laser Distance Sensor |
| Measuring Range | 200~10000mm (90% remission) |
| Resolution | 1 mm |
| Repeatability | 2.5 mm (1σ) |
| Accuracy | ±10 mm |
| Laser Class | Class 1, 658 nm red laser |
| Response Time | 20 ms / 30 ms selectable |
| Supply Voltage | DC 10 ~ 30 V |
| Digital Output | 1 × PNP, max 100 mA |
| Analog Output | 4 ~ 20 mA, 16 bit |
| Multi-function Input | 1 channel |
| Connector | M12 5-pin male |
| Protection Rating | IP65 |
| Housing Material | Zinc die cast |
| Dimension | 36.1 × 62.7 × 57.7 mm |
| Weight | Approx 200 g |
| Operating Temperature | -30 ℃ ~ +65 ℃ |
FAQ
1.Does the DT50-P1123 digital output support the function of switching between bright and dim states?
The Supports digital output polarity inversion, which means it can switch between on/off and on/off modes. This can be achieved by setting the output inversion in the sensor screen menu.
2.DT50-P1123 Multi-function Input MF has several function modes. How many are there?
Supported. The
- Laser shutdown mode: Once triggered, the laser stops emitting light and ceases measurement.
- External teaching mode: External signals are provided to complete threshold teaching.
- Input disable mode: The MF terminals do not perform any functions.
3.Can the display screen of DT50-P1123 be locked to prevent accidental modification of parameters?
The Support locking of the user interface. Once locked, the buttons on the rear panel cannot be used to modify parameters; only the measurement values can be viewed. This is to prevent accidental modifications to the settings in the field.
4.Does the DT50-P1123 support external teaching cable debugging?
The
- Support external teaching line debugging.
- Configure the MF multi-function input terminal to the external teaching mode. Connect an external switch or PLC point to trigger this terminal, and you can remotely set the teaching threshold without having to press the sensor panel buttons on-site.
Looking for Original New DT50-P1123 Dx50 Series Laser Sensor HDDM
We supply this DT50-P1123 mainly to system integrators and maintenance teams for replacement and retrofit projects.
Contact US to get a good prices now


Reviews