Overview
The Delta CP2000 Series Drive 75kW 100HP 150A Three-phase AC 460C D-frame, built-in PLC, supports hot-swappable LCD keyboard, supports remote network cable extension wiring for the panel, 6-pulse diode uncontrolled rectification, 3% DC reactor, suppresses grid harmonics and power-on surge current, multi-stage adjustable V/F curves, I/O expansion card, dual-axis module cooling fans, can be disassembled and replaced separately, IP20 sealed enclosure, full board 3C2 modified acrylic anti-corrosion coating, total machine net weight: 38.4kg
Specification
| Item | Specification |
|---|---|
| Model | VFD750CP43B-21 |
| Series | Delta CP2000 Fan & Pump Inverter |
| Rated Motor Power | 75kW (100HP) |
| Input Power | 3-phase 380~480V AC, 50/60Hz |
| ND Rated Current | 110A (Constant Torque) |
| LD Rated Current | 150A (Variable Torque) |
| ND Overload | 120%/60s, 160%/3s |
| LD Overload | 120%/60s |
| Max Output Frequency | 600Hz(V/F), 400Hz(SVC) |
| Control Mode | Multi V/F Curve, SVC Sensorless Vector |
| Built-in DC Reactor | Yes |
| Built-in EMC Filter | No |
| Built-in Brake Chopper | No |
| Cooling Fan | Modular, replaceable with life warning |
| PCB Coating | IEC 3C2 conformal coating |
| PLC Capacity | 10000 Steps |
| Max Pumps Linkage | 8 units |
| Native Communication | Modbus RTU, BACnet |
| Optional Bus Cards | Profibus-DP, CANopen, Modbus TCP, EtherNet/IP |
| Dimension(W×H×D) | 360mm × 690mm × 280mm |
| Net Weight | 38.4kg |
| Protection Class | IP20 |
| Full-load Ambient Temp | ND:-10~50℃; LD:-10~40℃ |
| Non-derating Altitude | ≤1000m |
| Certifications | CE, UL, cUL |
FAQ
1.What are the overall length, width and depth, as well as the total weight of the VFD750CP43B-21?
The
- IP20 D frame wall-mounted sealed type,
- Overall machine dimensions (width 360mm × height 690mm × depth 280mm)
- Net weight of the entire machine: 38.4kg
2.What is the maximum number of pumps that can be linked with one VFD750CP43B-21 inverter?
Supported. The
- Scheduled rotation mode (all pumps operate in alternate variable frequency): Up to 8 pumps are supported. To achieve 8-pump output logic, a multi-pump relay expansion card must be selected.
- Quantitative addition and subtraction pump mode (variable frequency + constant frequency mixed use): Up to 4 pumps are supported. 1 variable-frequency pump + up to 3 constant-frequency pumps. This is the most commonly used mode in constant pressure water supply projects.
3.What are the maximum output frequency and the low-frequency starting torque values for the VFD750CP43B-21V/F in the SVC mode?
The
- In the V/F (scalar) mode, the maximum output frequency is 600Hz.
- In the SVC (sensorless vector) mode, the maximum output frequency is 400Hz.
- In the SVC mode, the low-frequency starting torque at 0.5Hz: ≥ 160% of the motor’s rated torque.
4.How many steps are there in the built-in PLC program of VFD750CP43B-21?
The
- PLC program capacity: 10,000 steps (10K Steps)
- Equipped with an RTC (Real-Time Clock) perpetual calendar real-time clock, it supports timing control, time division start/stop, and multi-pump linkage logic programming.
- Using software to write ladder logic, local logic control of the pump room can be achieved without the need for an external independent PLC.
Looking for Original New Delta VFD750CP43B-21 CP2000 Series Drive 75kW 100HP 150A
We supply this VFD750CP43B-21 mainly to system integrators and maintenance teams for replacement and retrofit projects.
Contact US to get a good prices now


Reviews