The Delta VP3000 Series AC Motor Drive – Three-phase, 380-480 VAC, built-in DC reactor, built-in C3 level EMC filter, simple PLC program capacity of 20,000 steps, PID function, RS485 Modbus, RJ45 interface, USB-C debugging port, AI terminal supports PTC motor temperature detection, PCB three-layer anti-corrosion coating, LED operation panel, forced air cooling, wall-mounted installation, IP20.
Specification
| Item | Specification |
|---|---|
| Model | VFD180VP43AFTCA |
| Series | VP3000 Variable Torque Drive |
| Rated Motor Power | 90kW |
| Rated Output Current | 180A |
| Input | 3‑Phase 380‑480V,50/60Hz |
| Output Frequency | 0‑599Hz |
| Overload | 110% 1min per 5min(Light Duty) |
| Control Mode | V/F,SVC,PM Sensorless,SynRM Sensorless |
| STO Safety | Built‑in SIL3 |
| Built‑in PLC | Yes 20000 steps, PID integrated |
| Communication | RS485 Modbus,RJ45,USB‑C |
| Built‑in DC Reactor | Yes |
| Built‑in EMC Filter | Yes |
| Frame Size | H1 |
| Protection Class | IP20 |
| Dimensions(W×H×D) | 262mm × 710mm × 310mm |
| Weight | 34.2kg |
| Cooling | Forced air cooling,fan replaceable,no hot‑swap |
| DIN Rail Mount | Not supported |
| Operating Temp | ‑10℃ ~ +50℃ |
| Pollution Degree | 3C3 |
FAQ
1.What are the frame base dimensions, overall machine size and net weight of the VFD180VP43AFTCA model?
The
- Frame base: H1
- Overall machine dimensions (width 262 × height 660 × depth 258, units: mm)
- Net weight of the entire machine: 34.2 kg
2.How many DI, relay DO, AI and AO channels are onboard the VFD180VP43AFTCA board?
Supported. The
- Digital Input DI: 6 channels
- Relay Output DO: 2 channels
- Analog Input AI: 3 channels
- Analog Output AO: 2 channels
3.Does VFD180VP43AFTCAPID have the functions of multi-pump linkage and sleep-wake?
The The PID function is built-in on the device. It also has native functions such as sleep-wake and multi-pump linkage, and no additional accessory cards are required.
4.Does the VFD180VP43AFTCAAI terminal support PTC motor temperature detection?
The Support. One of the onboard AI terminals can be configured for PTC motor temperature detection, directly connected to the PTC thermistor of the motor, without the need for an external conversion module.
Looking for Original New Delta VFD180VP43AFTCA VP3000 Series AC Motor Drive 90kW 180A H1
We supply this VFD180VP43AFTCA mainly to system integrators and maintenance teams for replacement and retrofit projects.
Contact US to get a good prices now