Overview
The ABB ACS880-01-05A6-3 2.2 kW 5.6 A 400V 50/60Hz Three-phase 380 – 415V AC Built-in DC reactor ACS-AP-W Modbus RTU (Supports RS-485 for asynchronous motors, permanent magnet motors, synchronous reluctance motors, and inverters)
Specification
| Parameter | Specification |
|---|---|
| Model | ACS880-01-05A6-3 |
| Frame Size | R1 |
| Protection Grade | IP21 |
| Installation Method | Wall-mounted |
| Net Weight | 7 kg |
| Overall Dimensions | 409×155×226 mm |
| Input Power | 3-phase 380–415 V AC, 50/60 Hz |
| Light Duty Motor Power | 2.2 kW |
| Heavy Duty Motor Power | 1.5 kW |
| Continuous Output Current | 5.6 A |
| Light Overload Current | 5.3 A |
| Heavy Overload Current | 4.0 A |
| Short-time Maximum Current | 6.4 A |
| Output Frequency Range | 0~598 Hz |
| Control Mode | DTC, V/F control, Sensorless vector control |
| Applicable Motor Type | Asynchronous motor, Permanent magnet motor, SynRM motor |
| Digital Input | 6 channels (24 VDC) |
| Digital Output | 3 relay channels |
| Analog Input | 2 channels (0–10 V / 4–20 mA) |
| Analog Output | 2 channels (0–10 V / 4–20 mA) |
| Standard Communication | RS-485 Modbus RTU, USB |
| Optional Fieldbus | Profinet, EtherNet/IP, EtherCAT, Profibus-DP, CANopen |
| Standard Safety Function | STO (Safe Torque Off) |
| Safety Rating | SIL 3 / PL d |
| Built-in Configuration | EMC filter, DC reactor, Brake chopper |
| Protection Functions | Overvoltage, Undervoltage, Overcurrent, Short circuit, Overheating, Phase loss, Earth fault, Motor overload |
| Operating Temperature | -15 ℃ ~ +40 ℃ |
| Working Altitude | ≤1000 m (no derating) |
FAQ
1.What are the input power voltage and frequency specifications for the ACS880-01-05A6-3 inverter?
The Three-phase AC 380 – 415V, rated frequency 50/60Hz.
2.What are the output currents for the light load and heavy load modes of ACS880-01-05A6-3?
What is the value of the maximum short-term output current?
Supported. The
- Light load LD 5.3A
- Overload HD 4.0A
- Short-term maximum output current: 6.4A
3.What electrical and fault protection functions does the ACS880-01-05A6-3 inverter have?
The At the
- Overcurrent protection
- Short-circuit protection
- Ground fault protection
- Overvoltage protection
- Undervoltage protection
- Input phase loss protection
- Output phase loss protection
- Frequency converter overheating protection
- Motor overload protection
- Motor locked-rotor protection
- Motor underload protection
- Brake resistor overload protection
- Internal temperature control abnormality protection
- Parameter error protection
- Communication failure protection
- Power supply instantaneous power loss protection
- Power unit failure protection
- Electrical leakage monitoring protection
- Safety circuit STO failure protection
4.What is the number and type of the standard digital output ports for ACS880-01-05A6-3?
The
- Standard digital output: 3 channels
- Port type: Relay output
- Contact specification: 250V AC / 30V DC, load 2A