Overview
The SIEMENS SINAMICS G120 PM240-2 Power Module for 3AC 380-480V AC FSF Frame, LO: 90kW HO: 75KW, Built-in braking chopper, All IO provided by CU Control Unit, Built-in detachable cooling fan, No EMC Filter, Wall-mounted installation with screws on cabinet body, Main circuit M10 screw terminals, Metal casing, Engineering plastic front panel enclosure, Net weight: 57kg, IP20
Specification
| Item | 6SL3210‑1PE31‑8UL0 SINAMICS PM240‑2 Power Module |
|---|---|
| Series | SINAMICS G120 PM240‑2 |
| Input | 3AC 380‑480V +10/-20%,47‑63Hz |
| Low overload | 90kW,178A |
| High overload | 75kW,145A |
| Peak output current | 290A |
| Output frequency | 0‑550Hz |
| Brake chopper | Integrated |
| EMC filter | Not integrated |
| Frame size | FSF |
| Dimension(H×W×D) | 708mm ×305mm ×357mm |
| Weight | 57kg |
| Ingress Protection | IP20 |
| Mounting | Wall screw mounting |
FAQ
1.What is the frame model of 6SL3210-1PE31-8UL0? What are the overall height, width and thickness dimensions of the complete machine, as well as the net weight of the complete machine?
The
- Frame model: FSF
- Overall dimensions of the machine (height 708mm × width 305mm × depth 357mm)
- Net weight of the machine: 57kg
2.What is the specification of the main circuit terminal block for 6SL3210-1PE31-8UL0?
Supported. The
- Main circuit power supply and motor terminals: M10 bolts, requiring cable connectors, suitable for cable cross-sectional areas of 35 to 2×120 mm², tightening torque 22-25 Nm.
- Brake resistor terminals: Screw terminals, suitable for cable cross-sectional areas of 25-70 mm², tightening torque 8-10 Nm.
- PE grounding terminals: M10 bolts.
3.6SL3210-1PE31-8UL0 LO – This is a light-load general-purpose and HO heavy-load load-adapted motor power, continuous output current, overload curve?
The
- LO Light Load Normal Load: 90kW 178A (During the 300-second period, 50% overload lasts for 3 seconds, 110% overload lasts for 57 seconds, and the remaining 240 seconds are at 100% base current)
- HO Heavy Load: 75kW 145A (During the 300-second period, 200% overload lasts for 3 seconds, 150% overload lasts for 57 seconds, and the remaining 240 seconds are at 100% base current)
4.Does the 6SL3210-1PE31-8UL0 model have a built-in braking chopper? Should the braking resistor be built-in or external?
The Built-in braking chopper. The braking resistor needs to be externally connected. This machine does not have an internal braking resistor.
Looking for Original New 6SL3210‑1PE31‑8UL0 SIEMENS FSF 90kW 178A Power Module
We supply this 6SL3210‑1PE31‑8UL0 mainly to system integrators and maintenance teams for replacement and retrofit projects.
Contact US to get a good prices now


Reviews