Overview
The Siemens SIMATIC ET200M, IM153-4 PN IO PROFINET Distributed Interface Module, suitable for 12 S7-300 series modules. It supports MRP medium redundancy and 1-class and 2-class synchronous real-time communication at the same time. Rated DC 24V. It allows for replacing IO modules without programming devices PG. LINK green indicator light, RX/TX yellow indicator light. It has module diagnostic LED. It has electrical isolation and withstands 500V DC. DIN rail installation.
Specificatio
| Parameter | Value |
|---|---|
| Order number | 6ES7153-4AA01-0XB0 |
| Product type | IM 153-4 PN IO interface module |
| Series | SIMATIC ET200M |
| Fieldbus | PROFINET IO |
| Max S7-300 modules | 12 |
| Input address area | 192 byte |
| Output address area | 192 byte |
| Isochronous realtime | Class 1 and Class 2 |
| MRP media redundancy | Supported |
| Rated supply voltage | DC 24 V |
| Voltage range | 20.4 V ~ 28.8 V DC |
| Max current consumption | 600 mA |
| Backplane bus output | DC 5 V, max 1.5 A |
| Typical power loss | 6 W |
| Operation with MMC | Not required |
| Module replacement without PG | Supported |
| Weight | 0.263 kg |
| Installation | DIN rail mount |
| Software requirement | STEP7 V5.5 SP2 or higher |
FAQ
1.How many S7-300 modules can be expanded by a single IM153-4 PN IO unit with 6ES7153-4AA01-0XB0?
The
- Up to 12 S7-300 series modules (signal modules, function modules, and communication modules are all included) can be expanded.
- At the same time, it is subject to a 192-byte input and 192-byte output process image address limit.
2.When 6ES7153-4AA01-0XB0 replaces the IO module on-site, can the programming device PG be omitted
Supported. The
- Support for module without PG replacement.
- Under the condition that the corresponding function is enabled in the hardware configuration, replacing the same model S7-300 IO module does not require a programming device PG. Simply disconnect the power and replace the same model IO module directly. Note: This feature is applicable to S7-300 IO modules on the ET200M site.
3.What bus protocol is supported by the 6ES7153-4AA01-0XB0 module? Does it support MRP media redundancy?
The
- Bus protocol: PROFINET IO.
- Supports MRP medium redundancy and can act as an MRP client to connect to the PROFINET network.
4.Does 6ES7153-4AA01-0XB0 require an MMC memory card to run this interface module
The
- The operation does not require an MMC memory card.
- The IM153-4 PN IO interface module does not come with a program by itself. The program is stored in the upper-level PLC. The module can start working as soon as it is powered on, and there is no need for an MMC.
Looking for Original New 6ES7153-4AA01-0XB0 Siemens ET 200 Series PLC I/O Module
We supply this 6ES7153-4AA01-0XB0 mainly to system integrators and maintenance teams for replacement and retrofit projects.
Contact US to get a good prices now