Overview
The PowerFlex 525 25B-D2P3N104 AC variable frequency drive, three-phase, 380-480 V AC, built-in EtherNet/IP port (supporting DLR), 0.75 kW (1 HP) motor power, IP20 air-cooled, USB interface, no built-in EMC filter (external EMC filter can be used)
Specification
| Item | Specification |
|---|---|
| Model Number | 25B-D2P3N104 |
| Manufacturer | Allen-Bradley (Rockwell Automation) |
| Product Series | PowerFlex 525 |
| Product Type | Compact AC Variable Frequency Drive (VFD) |
| Input Voltage | 3-phase AC 380~480 V ±10% |
| Compatible Motor Power | 0.75 kW (1 HP), for both normal duty and heavy duty |
| Rated Output Current | 2.3 A |
| Output Voltage | 0~460 V AC |
| Switching Frequency | Default 4 kHz, selectable 2/8/16 kHz |
| Control Modes | V/F, Sensorless Vector Control (SVC), Closed-Loop Vector Control, Permanent Magnet Motor Control |
| Enclosure / Ingress Protection | IP20 (NEMA Open Type) |
| Frame Size | Frame A |
| Dimensions (W×H×D) | Approx. 23 mm × 100 mm × 120 mm |
| Cooling Method | Natural Air Cooling |
| Built-in Filter | None (external EMC filter optional) |
| Onboard Ethernet Port | Built-in EtherNet/IP port with DLR support |
| Other Communication Interfaces | USB (for programming), RS-485 (Modbus RTU) |
| I/O Configuration | 7 Digital Inputs (DI), 2 Digital Outputs (DO), 1 Analog Input (AI), 1 Analog Output (AO), 2 Relay Outputs |
| Operating Ambient Temperature | -10~+40 °C (derating above +50 °C) |
| Storage Temperature | -40~+70 °C |
| Standard Protection Functions | Overcurrent, Overload, Overvoltage, Undervoltage, Overtemperature, Ground Fault, Safe Torque Off (STO) |
| Rated Power Consumption | Approx. 37 W |
| Built-in Braking Unit | None (external braking resistor optional) |
FAQ
1.What control methods does 25B-D2P3N104 have?
The V/F open-loop control, sensorless vector SVC, closed-loop vector control, dedicated control for permanent magnet motors
2.What kind of cooling method does the 25B-D2P3N104 inverter use?
Supported. The Natural air cooling
3.What electrical protection functions does the 25B-D2P3N104 inverter have?
The Overcurrent, overload, overvoltage, undervoltage, overheating, ground fault, STO safety torque shutdown protection
4.How many digital quantities, analog quantities and relay points are configured for the 25B-D2P3N104 inverter?
The 7 digital inputs, 2 digital outputs, 1 analog input, 1 analog output, 2 relay outputs
Looking for Original New 25B-D2P3N104 Three Phase 380-480 V AC Sensorless Vector (SVC)
We supply this 25B-D2P3N104 mainly to system integrators and maintenance teams for replacement and retrofit projects.
Contact US to get a good prices now !


Reviews
There are no reviews yet.