Overview
The AB Kinetix 5700 is equipped with an internal LC input filter, supports parallel connection of multiple power supplies to expand output power, and includes feedback regeneration, voltage regulation, EtherNet/IP communication, CIP-Security safety function, LED status indicator panel, STO safety torque shutdown interface, 24V DC control power supply, 85 mm module width, two installation methods of DIN rail / backplate screw mounting, and supports zero stacking and close side-by-side installation. Its net weight is 7.04 kg.
Specification
| Item | Specification |
|---|---|
| Catalog No. | 2198‑P208 |
| Series | Kinetix 5700 DC‑Bus Supply |
| 3‑Phase Input Voltage | 324‑528V AC,47‑63Hz |
| Continuous Output Power | 46 kW |
| Peak Output Power | 138 kW |
| Continuous DC‑Bus Current | 69.2 A DC |
| Peak DC‑Bus Current | 207.6 A DC |
| Efficiency | 99% |
| Regenerative Function | Yes,energy feedback to AC line |
| Communication | EtherNet/IP, CIP security |
| Safety Function | STO Safe Torque‑Off interface |
| Dimension(W×H×D) | 85 mm × 432 mm × 233 mm |
| Weight | 7.04 kg |
| Operating Temp | 0~+50℃ |
| Protection Class | IP20 |
| Zero‑stacking | Supported |
FAQ
1.What type of module does 2198-P208 belong to in the Kinetix5700 series?
The
- DC bus power supply module (Bus Supply, bus power).
- It is equipped with a regenerative feedback function, which can return the regenerated energy from the motor back to the AC power grid without the need for an external braking resistor..
2.What are the continuous output power and peak output power of the 2198-P208 DC bus in kilowatts?
Supported. The
- Continuous output power of the DC bus: 46 kW
- Peak output power of the DC bus: 138 kW
- Note: The peak power is only allowed for a short period of time and is generated by the motor’s acceleration and impact load. It cannot be continuously output for a long time.
3.For the 2198-P208DC-BUS bus, what is the maximum distance that the external expansion can support for the inverter cluster? Is an intermediate bus fuse required?
The
- The maximum distance for a single-path external DC-BUS from the power cluster to the remote inverter cluster is 70 meters; the total length of the bus cables extending outward on both sides is capped at 140 meters.
- Within this 70-meter limit, no intermediate DC bus fuses need to be installed.
4.What is the maximum efficiency of the 2198-P208 module? What is the capacity of the internal bus capacitor?
The
- Overall machine efficiency: 99%
- Internal bus capacitor capacity: 2050 μF
- Additional information: Energy storage: 453 J; The module is equipped with a built-in discharge resistor of 13.5 Ω/200W. When the regenerated energy exceeds the grid’s feedback capacity, it will be discharged.