Overview
The AB Kinetix 5700 Capacitor Energy Storage Module, 600 V DC, 2240 μF, external DC-BUS terminals, 85 mm width, fixed by either DIN rail / M5 screw panel or other methods, supports zero stacking and side-by-side installation with close spacing, without EtherNet/IP communication chip, IP20 protection, overall dimensions (85 mm wide × 345 mm high × 253 mm deep), Note: This module cannot work independently; it needs to be used in combination with other power supplies and inverter modules.
Specification
| Item | Specification |
|---|---|
| Catalog No. | 2198‑CAPMOD‑2240 |
| Series | Kinetix 5700 Capacitor Module |
| Nominal DC‑Bus Voltage | 600 V DC(458‑747V DC operating) |
| Internal Capacitance | 2240 µF |
| Max External DC‑Bus Current | 104 A |
| Control Power | 24 VDC from backplane |
| Communication | None, only status LED |
| STO Safety | Not supported |
| Dimension(W×H×D) | 85 mm × 345 mm × 253 mm |
| Weight | 4.2 kg |
| Operating Temp | 0~+50℃ |
| Protection | IP20 |
| Zero‑stacking installation | Supported |
FAQ
1.What are the rated voltage and the allowable operating voltage range for the 2198-CAPMOD-2240 DC bus?
The
- Rated voltage of the DC bus: 600 V DC
- Allowable operating voltage range: 458 V DC ~ 747 V DC
2.Where does the 24V control power supply of the 2198-CAPMOD-2240 module obtain its power from?
Supported. The Backplane bus acquisition of the Kinetix5700 system. It is not possible to directly connect a 24V control power supply to this module externally.
3.Which Kinetix5700 power supplies and inverter modules can the 2198-CAPMOD-2240 module be used in combination with?
The
- Hiperface‑DSL (Single Cable Servo Encoder)
- EnDat 2.2 (Digital Absolute Value, Single Loop / Multiple Loops)
- TTL Incremental Encoder (A/B/Z)
- Sine/Cosine Positive/Negative Incremental Encoder
4.When the 2198‑CAPMOD‑2240 module is used alone, what is the maximum allowable continuous current in amperes for the external DC bus? If the current exceeds this value, which module needs to be combined with it?
The
- When using the 2198-CAPMOD-2240 unit alone, the maximum allowable continuous current of the external DC bus: 104 A.
- If the external bus current exceeds 104A, up to 208A under the worst conditions, it needs to be used in parallel with the DC bus expansion module.
Looking for Original New 2198‑CAPMOD‑2240 Kinetix 5700 Capacitor Energy Storage Module
We supply this 2198‑CAPMOD‑2240 mainly to system integrators and maintenance teams for replacement and retrofit projects.
Contact US to get a good prices now


Reviews
There are no reviews yet.