Overview
The AB ControlLogix series 16-channel current-type HART analog input module with 4 to 20mA and 0 to 20mA signal ranges. The channels are isolated from the backplane. 5V backplane, 230mA, 24V backplane 100mA. Removable spring terminals. Support for hot swapping. Each channel can be independently shut down. Status indicator light.
Specificatio
| Item | Specification |
|---|---|
| Part Number | 1756-IF16H |
| Series | ControlLogix |
| Module Type | HART Analog Input Module |
| Channel Quantity | 16 differential current input channels |
| Signal Type | Current only, no voltage input |
| Signal Range | 4~20mA, 0~20mA |
| HART Revision | HART5, HART6, HART7 |
| Resolution | 15~16 bit |
| Isolation | Isolation between channel bank and backplane, no channel-to-channel isolation |
| Minimum Analog Sample Time | 12ms |
| Backplane Current Draw 5V DC | 230mA |
| Backplane Current Draw 24V DC | 100mA |
| Terminal Type | Removable spring terminal block |
| Hot Swap Support | Yes |
| Individual Channel Disable | Yes |
| Independent Channel Filter | Yes |
| Operating Temperature | 0℃ to 60℃ |
| Origin | Mexico |
| Warranty | 1 year standard factory warranty |
FAQ
1.Are there any isolations between the 1756-IF16H channels?
The There is no isolation between the channels, but there is a basic insulation isolation between the input side and the backplane.
2.1756-IF16H supports the option to disable individual channels?
Supported. The support channels can be disabled independently. In the Studio 5000 software, each channel can be set to “Disabled”.
After being disabled, the channels no longer participate in signal acquisition and will not report open-circuit faults. They are suitable for idle channels that have not been connected.
3.Does 1756-IF16H support installation in any slot of the rack?
The
- It is an ordinary I/O module and can be installed in any I/O slot except the power module dedicated slot on the 1756 standard rack.
- Note that the leftmost position of the rack is the dedicated slot for the power module and this I/O module cannot be inserted there.
4.Can 1756-IF16H be used in conjunction with ordinary non-HART 4 to 20mA transmitters?
The
- It can be used in conjunction with ordinary non-HART 4 to 20mA transmitters.
- Ordinary transmitters only transmit 4 to 20mA analog signals. The module only reads the current value and will not initiate HART inquiries, so they do not affect each other.
Looking for Original New 1756-IF16H ControlLogix 16 Pt A/I HART Module
We supply this 1756-IF16H mainly to system integrators and maintenance teams for replacement and retrofit projects.
Contact US to get a good prices now