How to Choose the Right PLC: 4 Key Factors and Mitsubishi FX5U Series Guide

Table of Contents

1. Introduction: Why Choosing the Right PLC Matters

A Programmable Logic Controller (PLC) is the core control component of modern industrial automation systems. It receives signals from sensors, processes control logic, and sends commands to motors, valves, relays, and other equipment.

Choosing the right PLC is essential for ensuring stable machine operation, improving production efficiency, and reducing maintenance costs. However, selecting a PLC based only on the number of input and output points is a common mistake.

A suitable PLC must meet several important requirements, including I/O capacity, analog signal processing, communication compatibility, and motion control performance.

For example, a machine may require only 30 digital I/O points but also need to process temperature signals from a PT100 sensor, read a 4–20 mA pressure transmitter, and generate a 0–10 V control signal for a power regulation module. A basic digital PLC without analog capabilities cannot handle these requirements without additional hardware.

This can lead to extra costs, cabinet modifications, wiring changes, and commissioning delays.

In this guide, we will explain four important factors to consider when selecting an industrial PLC. We will also introduce the Mitsubishi FX5U series, part of the iQ-F platform, and provide a reference list of 40 related PLC models, expansion modules, and accessories.

Whether you are designing a new automation system, upgrading existing machinery, or selecting replacement components, understanding these factors will help you make a more informed decision.

2. I/O Points: Calculate Requirements and Reserve Expansion Capacity

The first step in PLC selection is determining the required number of input and output points.

PLC I/O points are generally divided into four categories:

  • DI (Digital Input): Receives signals from sensors, push buttons, limit switches, and other digital devices.
  • DO (Digital Output): Controls relays, contactors, solenoid valves, indicator lights, and other output devices.
  • AI (Analog Input): Receives continuous signals such as 0–10 V and 4–20 mA.
  • AO (Analog Output): Sends analog control signals to variable frequency drives, valves, and other equipment.

A common mistake is selecting a PLC whose I/O capacity exactly matches the current requirements.

Industrial machines often require modifications after commissioning. Additional sensors, alarm indicators, switches, and control devices may be installed as production requirements change.

Recommended practice: Reserve approximately 15%–25% additional I/O capacity.

For example, consider a packaging line with the following requirements:

I/O Type Required Points
Digital Inputs 80
Digital Outputs 60
Analog Inputs 4
Analog Outputs 2
Total 146

Although a 160-point PLC configuration may appear sufficient, it leaves limited room for future expansion.

If the customer later requests additional temperature sensors and alarm indicators, the original configuration may need additional expansion modules.

Therefore, it is important to calculate not only the current I/O requirements but also the expected expansion capacity.

Engineers should also check the electrical characteristics of each I/O point, including:

  • 24 VDC or 220 VAC requirements
  • PNP or NPN sensor compatibility
  • Relay or transistor output type
  • Input and output current ratings
  • High-speed counting requirements
  • Dedicated positioning and communication functions

A detailed I/O list prepared before purchasing the PLC can prevent unnecessary hardware changes during installation.

3. Analog Signal Processing: Check Signal Types and Resolution

Analog signal processing is essential in applications involving temperature, pressure, flow, liquid level, and other continuously changing process variables.

Unlike digital signals, which generally have ON and OFF states, analog signals represent a range of values.

Common industrial analog signal types include:

Signal Type Typical Application
0–10 V Drive speed and position control
4–20 mA Pressure, flow, and level measurement
PT100 RTD Temperature measurement
Thermocouple High-temperature measurement

When selecting a PLC, engineers should confirm whether the CPU has built-in analog channels or requires additional analog expansion modules.

3.1 Understanding Analog Resolution

Analog resolution determines how finely an analog signal can be converted into digital values.

Common resolutions include 12-bit and 16-bit configurations.

A 12-bit converter provides 4,096 possible digital values, while a 16-bit converter provides 65,536 possible values.

Higher resolution allows smaller changes in the measured signal to be represented.

For applications requiring accurate temperature, pressure, or flow control, a higher-resolution analog module may be beneficial.

However, actual measurement accuracy also depends on module specifications, sensor accuracy, signal conditioning, wiring, and environmental conditions. Resolution alone does not determine total system accuracy.

3.2 Choosing the Correct Analog Signal Type

Different signal types are suitable for different applications.

4–20 mA signals: Commonly used in industrial environments because current-loop transmission is relatively resistant to voltage drop over long cables. It can also help identify certain wiring faults.

0–10 V signals: Frequently used for variable frequency drive speed references and other analog control applications. They are convenient for shorter signal connections but require appropriate noise protection.

PT100 and thermocouple signals: Used for temperature measurement. These sensors generally require dedicated temperature input modules or suitable signal conditioners.

For example, a constant-pressure water supply system may use a 4–20 mA pressure transmitter connected to a PLC analog input. The PLC processes the pressure value and adjusts the variable frequency drive through a PID control algorithm.

For stable operation, the selected analog module must support the transmitter’s signal type, required measurement range, and accuracy.

It is also important to consider electrical isolation and noise immunity, especially in control cabinets containing large VFDs and servo drives.

4. Communication Compatibility: Make Sure All Devices Can Connect

Modern industrial automation systems usually contain multiple devices that need to exchange information.

These devices may include:

  • PLC controllers
  • Human Machine Interfaces (HMIs)
  • Variable Frequency Drives (VFDs)
  • Servo drives
  • Industrial robots
  • Remote I/O modules
  • SCADA and MES systems

Communication compatibility should be checked before selecting a PLC.

A controller that does not support the required communication protocol may need additional modules or protocol gateways, increasing system complexity and cost.

4.1 Common Industrial Communication Protocols

RS-485 / Modbus RTU

Modbus RTU is widely used for communication between PLCs, variable frequency drives, temperature controllers, and industrial instruments.

It is a practical option for many low- and medium-speed field communication applications.

Ethernet / Modbus TCP

Modbus TCP is commonly used for communication between PLCs, HMIs, industrial computers, and supervisory systems.

Ethernet connectivity also makes remote monitoring and engineering access easier when properly configured.

PROFINET and EtherCAT

These industrial Ethernet protocols are used in applications requiring real-time communication and coordinated automation.

Their suitability depends on the PLC, communication modules, connected devices, and required synchronization performance.

4.2 Check Native Communication Support

Before purchasing a PLC, identify the communication protocols required by every connected device.

Check whether the selected CPU supports these protocols directly or requires an additional communication module.

Native communication support can simplify configuration, reduce hardware requirements, and make system maintenance easier.

For new machine designs, an Ethernet-equipped PLC is often a practical choice because it provides more flexibility for future integration with HMIs, drives, and upper-level monitoring systems.

5. Motion Control: Consider Axis Numbers and Positioning Accuracy

Motion control is another important factor in PLC selection, particularly for machines using servo motors and stepper motors.

Applications such as automatic dispensing, cutting machines, packaging equipment, and precision assembly systems may require accurate positioning and coordinated movement.

Three important parameters should be considered:

  1. Number of controlled axes
  2. Positioning accuracy and synchronization requirements
  3. Maximum pulse output frequency and communication cycle

5.1 Understanding Pulse Output Frequency

Many stepper and servo systems use pulse-and-direction signals for position commands.

The pulse frequency determines how quickly the motor receives movement commands.

A PLC with limited pulse output frequency may not be suitable for high-speed positioning applications.

Therefore, engineers should check the maximum pulse frequency supported by the selected CPU and its dedicated positioning modules.

5.2 Relay Output vs. Transistor Output

Output type is particularly important when controlling stepper and servo drives.

Relay outputs (MR): Suitable for switching contactors, relays, and other relatively low-frequency control loads.

Transistor outputs (MT): Suitable for high-speed pulse output applications when the PLC model supports the required positioning functions.

Relay outputs should not be used to generate high-frequency motion-control pulses because their switching speed and mechanical contact life are unsuitable for this application.

For machines requiring multiple coordinated axes, dedicated positioning modules or motion controllers may be necessary.

The correct solution depends on axis count, interpolation requirements, control cycle, and the performance specifications of the connected drives.

6. Mitsubishi FX5U Series: A Practical PLC Solution for Industrial Automation

The Mitsubishi FX5U series belongs to the iQ-F PLC platform and is designed for small and medium-sized industrial automation applications.

It provides a combination of built-in control functions, expandable I/O, Ethernet connectivity, and optional analog and positioning modules.

The FX5U family includes different CPU configurations with relay and transistor outputs, allowing engineers to select a suitable model according to machine requirements.

6.1 Main Features of Mitsubishi FX5U PLCs

  • Multiple digital I/O configurations
  • Relay and transistor output options
  • Built-in Ethernet communication on applicable CPU models
  • Expandable digital I/O
  • Optional analog input and output modules
  • Positioning and motion-control expansion options
  • Communication expansion for industrial networks
  • Integration with Mitsubishi automation equipment

6.2 FX5U and FX5UC CPU Options

The FX5U series provides different I/O capacities, including 32-point, 64-point, and 80-point configurations.

FX5UC models offer a more compact CPU design and are available in transistor-output configurations.

When selecting a CPU, engineers should consider the required I/O capacity, output type, power supply requirements, installation space, and expansion options.

The FX5U family is commonly considered for packaging machinery, assembly equipment, conveyor systems, and general industrial automation.

7. Forty Mitsubishi FX5U Series Models and Related Modules

The following list provides 40 representative Mitsubishi FX5U and FX5UC product designations, including CPU units, I/O expansion modules, analog modules, positioning modules, and communication modules.

7.1 Mitsubishi FX5U CPU Units

No. Model Number Description
1 FX5U-32MR/ES 32 I/O, relay output
2 FX5U-32MT/ES 32 I/O, transistor output
3 FX5U-32MT/ESS 32 I/O, transistor output, sink
4 FX5U-32MR/DS 32 I/O, relay output
5 FX5U-32MT/DS 32 I/O, transistor output
6 FX5U-32MT/DSS 32 I/O, transistor output
7 FX5U-64MR/ES 64 I/O, relay output
8 FX5U-64MT/ES 64 I/O, transistor output
9 FX5U-64MT/ESS 64 I/O, transistor output, sink
10 FX5U-64MR/DS 64 I/O, relay output
11 FX5U-64MT/DS 64 I/O, transistor output
12 FX5U-64MT/DSS 64 I/O, transistor output
13 FX5U-80MR/ES 80 I/O, relay output
14 FX5U-80MT/ES 80 I/O, transistor output
15 FX5U-80MT/ESS 80 I/O, transistor output, sink
16 FX5U-80MR/DS 80 I/O, relay output
17 FX5U-80MT/DS 80 I/O, transistor output
18 FX5U-80MT/DSS 80 I/O, transistor output

7.2 Mitsubishi FX5UC Compact CPU Units

No. Model Number Description
19 FX5UC-32MT/D 32 I/O, transistor output
20 FX5UC-32MT/DSS 32 I/O, transistor output, sink
21 FX5UC-64MT/D 64 I/O, transistor output
22 FX5UC-64MT/DSS 64 I/O, transistor output, sink

7.3 Mitsubishi FX5 Digital I/O Expansion Modules

No. Model Number Description
23 FX5-8EX 8 digital inputs
24 FX5-16EX 16 digital inputs
25 FX5-8EYR 8 relay outputs
26 FX5-8EYT 8 transistor outputs
27 FX5-16EYR 16 relay outputs
28 FX5-16EYT 16 transistor outputs
29 FX5-32ER 16 inputs / 16 relay outputs
30 FX5-32ET 16 inputs / 16 transistor outputs

7.4 Mitsubishi FX5 Analog Modules and Adapters

No. Model Number Description
31 FX5-4AD 4-channel analog input
32 FX5-8AD 8-channel analog input
33 FX5-4DA 4-channel analog output
34 FX5-4AD-ADP Analog input adapter
35 FX5-4DA-ADP Analog output adapter
36 FX5-4A-ADP 2 analog inputs / 2 analog outputs

7.5 Mitsubishi FX5 Positioning and Communication Modules

No. Model Number Description
37 FX5-20PG-P 2-axis pulse generator
38 FX5-40SSC-S 4-axis SSCNET module
39 FX5-80SSC-S 8-axis SSCNET module
40 FX5-16CCL-M CC-Link IE master module

Note: The above list is a reference based on Mitsubishi FX5U/iQ-F product designations. It includes CPUs and expansion modules rather than 40 individual CPU models. Always verify complete ordering codes, electrical specifications, output configurations, compatibility, and product availability using the latest Mitsubishi documentation before purchasing.

8. Common Applications of Mitsubishi FX5U PLCs

Packaging Machinery

FX5U PLCs can be used to control product detection, conveyor movement, filling operations, sealing equipment, and packaging sequences.

Photoelectric sensors provide product detection signals, while PLC outputs control motors, valves, and other equipment.

Automated Assembly Lines

Assembly machines require accurate coordination between sensors, pneumatic cylinders, motors, and mechanical positioning devices.

The FX5U platform provides digital I/O and expansion options for different machine configurations.

Water Treatment Systems

Water treatment equipment frequently requires analog signal processing for pressure, flow, temperature, and liquid-level monitoring.

Suitable analog input modules allow the PLC to collect process data and execute control logic.

Conveyor Systems

Conveyor applications use sensors to detect products and control material movement.

PLC communication functions can also support integration with variable frequency drives and HMI systems.

Motion Control Equipment

For suitable applications, FX5U positioning modules can support stepper and servo-related control tasks.

The actual motion capability depends on the selected CPU, positioning hardware, communication configuration, and connected drive.

9. Frequently Asked Questions (FAQ)

Q1: What are the four most important factors when selecting a PLC?

The four main factors are I/O capacity, analog signal processing, communication protocol compatibility, and motion control capability. All four should be evaluated before purchasing a PLC.

Q2: How much spare I/O capacity should a PLC have?

A practical recommendation is to reserve approximately 15%–25% additional I/O capacity. This provides room for future machine modifications and additional sensors or control devices.

Q3: What is the difference between digital and analog PLC inputs?

Digital inputs receive ON/OFF signals from devices such as push buttons and proximity sensors. Analog inputs receive continuously varying signals such as 0–10 V and 4–20 mA.

Q4: Why is 4–20 mA commonly used in industrial automation?

A 4–20 mA current loop is relatively resistant to voltage drop and electrical interference over long cable distances. It can also help identify certain open-circuit wiring faults.

Q5: What is the difference between 12-bit and 16-bit analog resolution?

A 12-bit converter provides 4,096 digital levels, while a 16-bit converter provides 65,536 levels. Higher resolution allows finer signal representation, although overall measurement accuracy depends on the complete measurement system.

Q6: Can all PLCs control servo motors?

No. Servo control requires compatible output hardware, communication interfaces, or dedicated positioning functions. The PLC must support the required pulse frequency, axis count, and synchronization performance.

Q7: What is the difference between Mitsubishi FX5U and FX5UC?

Both belong to Mitsubishi’s iQ-F PLC platform. FX5U offers different CPU configurations and I/O capacities, while FX5UC features a more compact design. Their expansion and installation requirements should be checked individually.

Q8: What is the difference between relay and transistor PLC outputs?

Relay outputs use mechanical contacts and are suitable for general switching applications. Transistor outputs support faster switching and are commonly used for high-speed pulse control when supported by the PLC model.

Q9: Does the Mitsubishi FX5U support Ethernet communication?

Applicable FX5U CPU models provide built-in Ethernet connectivity. The exact communication functions and supported protocols should be confirmed in the technical manual for the selected CPU.

Q10: How do I choose the correct Mitsubishi FX5U model?

Start by calculating the digital and analog I/O requirements, then check the output type, communication protocols, positioning requirements, and future expansion needs. Finally, compare the complete CPU and expansion module specifications before ordering.

10. Conclusion: Make PLC Selection Easier with a Structured Checklist

Choosing the right PLC is about much more than counting input and output points.

A reliable PLC selection process should evaluate four essential factors:

  • I/O capacity: Calculate actual requirements and reserve 15%–25% expansion capacity.
  • Analog performance: Check signal types, resolution, isolation, and noise immunity.
  • Communication: Confirm protocol compatibility with all connected industrial devices.
  • Motion control: Evaluate axis numbers, pulse frequency, and positioning requirements.

The Mitsubishi FX5U series provides a flexible PLC platform for many small and medium industrial automation applications. With different CPU configurations and a wide range of expansion options, it can support applications involving digital control, analog processing, communication, and positioning.

By understanding these four selection factors and comparing the appropriate FX5U models, engineers and machine builders can reduce unnecessary hardware costs, simplify commissioning, and improve long-term system reliability.

A well-planned PLC configuration is an important foundation for efficient and dependable industrial automation.