ELAU Automation Systems: Common Fault Codes, Troubleshooting Guide, and 40 Popular ELAU Part Numbers
Introduction
ELAU was one of the most respected motion control and automation brands in the packaging machinery industry. Originally founded in Germany, ELAU became well known for its integrated servo systems, PacDrive controllers, servo drives, servo motors, and machine automation solutions used in food processing, pharmaceutical manufacturing, packaging equipment, and industrial machinery.
In 2010, ELAU became part of Schneider Electric, and many ELAU technologies were gradually integrated into the PacDrive platform under Schneider Electric’s Machine Automation portfolio.
Today, thousands of machines worldwide still operate using ELAU controllers, servo drives, and servo motors. As these systems age, maintenance engineers frequently encounter fault codes, communication alarms, and hardware replacement challenges.
This guide provides an overview of ELAU systems, common error codes, troubleshooting methods, and a reference list of popular ELAU part numbers.
What Is the ELAU PacDrive System?
The ELAU PacDrive architecture combines:
- Motion Controllers
- Servo Drives
- Servo Motors
- Distributed I/O Modules
- Machine Automation Software
The system was designed to simplify machine architecture by integrating motion control and PLC functions into a single platform.
Common ELAU product families include:
PacDrive Controllers
- C200
- C400
- C600
- C200A
- C400A
Servo Drives
- MC-4 Series
- MC-4/11 Series
- MC-4/11/10 Series
Servo Motors
- SH Series
- ISH Series
- SM Series
Power Supplies and Accessories
- VDM Series
- VCA Series
- Power Distribution Modules
Common ELAU Fault Codes and Troubleshooting
Although exact alarm descriptions vary by firmware version, the following faults are among the most frequently reported by maintenance technicians.
Error 1001 – Communication Failure
Description
The controller cannot communicate with one or more servo drives.
Possible Causes
- Ethernet connection failure
- Damaged communication cable
- Incorrect node addressing
- Controller reboot
Recommended Actions
- Verify Ethernet cable connections.
- Check network configuration.
- Confirm drive node addresses.
- Restart controller and drives.
- Review communication diagnostics.
Error 1002 – Servo Drive Not Ready
Description
The servo drive remains in a disabled state and cannot enter operation mode.
Possible Causes
- Missing enable signal
- Emergency stop active
- Power supply issue
- Drive fault condition
Recommended Actions
- Verify machine safety circuits.
- Check emergency stop status.
- Confirm 24VDC control voltage.
- Reset the servo drive.
Error 2001 – Motor Overtemperature
Description
The motor temperature exceeds the configured protection threshold.
Possible Causes
- Excessive load
- Insufficient cooling
- High ambient temperature
- Damaged temperature sensor
Recommended Actions
- Reduce motor load.
- Improve cabinet ventilation.
- Check cooling fans.
- Inspect motor temperature feedback wiring.
Error 2002 – Overcurrent Alarm
Description
The drive detects current exceeding safe operating limits.
Possible Causes
- Mechanical jam
- Motor winding fault
- Incorrect tuning parameters
- Sudden load changes
Recommended Actions
- Inspect mechanical system.
- Check motor insulation.
- Verify drive parameters.
- Review acceleration settings.
Error 3001 – Encoder Feedback Error
Description
The drive receives invalid encoder signals.
Possible Causes
- Damaged encoder cable
- Loose connector
- Encoder failure
- Electrical interference
Recommended Actions
- Inspect encoder connections.
- Replace damaged cables.
- Check shielding and grounding.
- Test encoder operation.
Error 3002 – Position Following Error
Description
Actual motor position differs significantly from commanded position.
Possible Causes
- Excessive machine load
- Servo tuning issues
- Mechanical slippage
- Encoder problems
Recommended Actions
- Check couplings and belts.
- Optimize servo tuning.
- Verify encoder feedback.
- Inspect mechanical components.
Error 4001 – DC Bus Overvoltage
Description
DC bus voltage exceeds drive operating limits.
Possible Causes
- Regenerative energy during deceleration
- Braking resistor failure
- Unstable incoming power
Recommended Actions
- Inspect braking resistor.
- Increase deceleration time.
- Verify supply voltage.
Error 4002 – DC Bus Undervoltage
Description
Supply voltage drops below minimum operating level.
Possible Causes
- Power interruption
- Weak power supply
- Loose wiring
Recommended Actions
- Measure input voltage.
- Inspect power terminals.
- Verify power supply capacity.
Error 5001 – Drive Overload
Description
The drive operates beyond rated capacity.
Possible Causes
- Undersized drive
- Continuous high torque demand
- Mechanical resistance
Recommended Actions
- Review application sizing.
- Check machine mechanics.
- Monitor motor current.
Error 5002 – Internal Drive Fault
Description
Internal hardware malfunction detected.
Possible Causes
- Power module failure
- Control board issue
- Firmware corruption
Recommended Actions
- Cycle power.
- Update firmware if applicable.
- Replace drive if fault persists.
Preventive Maintenance Tips for ELAU Systems
To maximize equipment reliability:
Inspect Servo Connections
Regularly check:
- Motor power cables
- Encoder cables
- Communication networks
Clean Electrical Cabinets
Dust accumulation can cause:
- Overheating
- Cooling issues
- Premature component failure
Monitor Drive Temperatures
Keep:
- Ventilation filters clean
- Cooling fans operational
- Ambient temperatures within specifications
Backup Controller Programs
Always maintain:
- Machine programs
- Motion configurations
- Parameter backups
This minimizes downtime when hardware replacement becomes necessary.
40 Popular ELAU Part Numbers
The following ELAU products are commonly found in industrial automation and packaging applications.
| No. | ELAU Part Number |
|---|---|
| 1 | SH070/60011/0/0/00/00/00/00/00 |
| 2 | SH070/60030/0/0/00/00/00/00/00 |
| 3 | SH100/40060/0/0/00/00/00/00/00 |
| 4 | SH100/60060/0/0/00/00/00/00/00 |
| 5 | SH140/30070/0/0/00/00/00/00/00 |
| 6 | SH140/60070/0/0/00/00/00/00/00 |
| 7 | SH205/40080/0/0/00/00/00/00/00 |
| 8 | SH205/60080/0/0/00/00/00/00/00 |
| 9 | ISH070/60011/0/0/00/0/00/10/00 |
| 10 | ISH070/60030/0/0/00/0/00/10/00 |
| 11 | ISH100/40060/0/0/00/0/00/10/00 |
| 12 | ISH100/60060/0/0/00/0/00/10/00 |
| 13 | ISH140/30070/0/0/00/0/00/10/00 |
| 14 | ISH140/60070/0/0/00/0/00/10/00 |
| 15 | ISH205/40080/0/0/00/0/00/10/00 |
| 16 | ISH205/60080/0/0/00/0/00/10/00 |
| 17 | MC-4/11/10/400 |
| 18 | MC-4/11/22/400 |
| 19 | MC-4/11/35/400 |
| 20 | MC-4/11/50/400 |
| 21 | MC-4/11/75/400 |
| 22 | MC-4/11/100/400 |
| 23 | MC-4/11/10/230 |
| 24 | MC-4/11/22/230 |
| 25 | MC-4/11/35/230 |
| 26 | MC-4/11/50/230 |
| 27 | C200/10/1/1/1/00 |
| 28 | C200/10/1/1/1/01 |
| 29 | C400/A8/1/1/1/00 |
| 30 | C400/10/1/1/1/00 |
| 31 | C600/10/1/1/1/00 |
| 32 | C600/A8/1/1/1/00 |
| 33 | VCA07AAAA0AA00 |
| 34 | VCA09AAAA0AR00 |
| 35 | VDM01D10AA000 |
| 36 | VDM01U30AA0 |
| 37 | VDM02D20AA00 |
| 38 | VDM02U40AA0 |
| 39 | MA-0005-100 |
| 40 | MA-0010-200 |
Migration and Replacement Considerations
Many original ELAU products are now considered legacy equipment. In some cases:
- Direct replacements remain available through Schneider Electric.
- Refurbished units may be the only option.
- Firmware compatibility should be verified before replacement.
- Servo motors and drives should be matched carefully to maintain machine performance.
When replacing older ELAU hardware, engineers should always review:
- Firmware versions
- Encoder compatibility
- Drive parameter settings
- Motion application requirements
Improper replacement can result in communication errors, tuning problems, or machine downtime.
Conclusion
ELAU automation systems remain widely used across packaging, food processing, pharmaceutical, and manufacturing industries. Understanding common fault codes, maintenance procedures, and hardware compatibility can significantly reduce downtime and extend equipment life.
Whether you are maintaining a PacDrive controller, troubleshooting an MC-4 servo drive, or replacing an SH or ISH servo motor, proper diagnostics and preventive maintenance are essential for long-term reliability.
PLC Provised ltdprovides technical support, troubleshooting assistance, and original new industrial automation products. We can supply ELAU controllers, servo drives, servo motors, as well as PLC modules, HMI panels, VFDs, and automation spare parts from major brands including Siemens, Allen-Bradley, Schneider Electric, Mitsubishi, ABB, Omron, and more.