Overview
The Delta CP2000 Series AC Drive 460V Three-phase F2 Frame With Built-in DC Reactor, Built-in PLC10000 Step, Constant Pressure Water Supply, PCB Circuit Board with Class3C2 Three-Protect Coating, Forced Air Cooling, Fan Life Warning, LCD Operation Panel, Supports Remote RJ45 Extension, Wall-Hung Screw Installation, IP20 Enclosed Cabinet Version
Specification
| Item | Specification |
|---|---|
| Model | VFD1320CP43B‑21 |
| Series | CP2000 Fan‑Pump Drive |
| Rated motor power | 132kW(175HP),3‑phase 380‑480V |
| Frame size | F2 |
| Output current ND/LD | 240A / 260A |
| Rectifier | 6‑pulse |
| Built‑in DC reactor | Yes |
| Built‑in EMC filter | No |
| Built‑in braking chopper | No |
| Built‑in PLC steps | 10000 steps(RTC real‑time clock) |
| Max pump quantity | 8 pumps |
| Dimension(W×H×D) | 480 mm × 840 mm × 330 mm |
| Weight | 91.0 kg |
| Cooling | Forced air cooling,replaceable modular fan |
| Enclosure rating | IP20 |
| Keypad | KPCC‑01,support remote extension |
| PCB Conformal coating | Class3C2 |
| Operation temp full rating | 0‑50℃ |
FAQ
1.VFD1320CP43B-21 – Overall width, height and depth dimensions of the machine, net weight of the machine, frame model?
The
- Frame model: F2 frame
- Overall dimensions of the machine (width 480 mm × height 840 mm × depth 330 mm)
- Net weight of the machine: 91.0 kg
2.The maximum output frequency of the VFD1320CP43B-21V/F mode and the SVC mode. What is the low-frequency starting torque of the SVC mode at 0.5Hz?
Supported. The
- In the V/F mode, the maximum output frequency is 599 Hz.
- In the SVC (unmechanically sensed vector) mode, the maximum output frequency is also 599 Hz.
- In the SVC mode, the low-frequency starting torque at 0.5 Hz is 150% of the rated torque.
3.For the VFD1320CP43B-21 model, how many pulses does the rectification have? Is it equipped with an internal DC reactor, EMC filter, and braking chopper?
The
- Rectification structure: 6-pulse rectification
- DC reactor: Built-in standard configuration
- EMC filter and braking chopper: No built-in, requires external selection
4.What model of operation panel is VFD1320CP43B-21? Does it support remote extension? What is the maximum wiring distance in meters?
The
- Standard factory-installed operation panel: KPC-CC01 LCD operation panel
- Remote extension wiring: Supported, RJ45 interface
- Official maximum stable wiring distance: 5m (16 feet)
Looking for Original New VFD1320CP43B-21 Delta CP2000 Series AC Drive 132kW 175HP 260A
We supply this VFD1320CP43B-21 mainly to system integrators and maintenance teams for replacement and retrofit projects.
Contact US to get a good prices now


Reviews