The Delta CP2000 Series Drive, 460V, 125HP, LD180A, ND150A, D1 frame, built-in DC reactor, built-in PLC, supports sequential logic control, constant pressure water supply, built-in Modbus-RTU, IP20 enclosed cabinet version, PCB circuit board with three-layer anti-corrosion coating, forced air cooling, supports individual disassembly and replacement, equipped with fan life warning, LCD operation panel, supports remote extension of wiring on the panel, wall-mounted screw installation.
Specification
| Item | Specification |
|---|---|
| Model | VFD900CP43A‑21 |
| Series | CP2000 Fan‑Pump Drive |
| Rated motor power | 90kW(125HP),3‑phase 380‑480V |
| Frame size | D1 |
| Output current ND/LD | 150A / 180A |
| Rectifier | 6‑pulse |
| Built‑in DC reactor | Yes |
| Built‑in EMC filter | No |
| Built‑in braking chopper | No |
| Built‑in PLC steps | 10000 steps(RTC real‑time clock) |
| Max pump quantity | 8 pumps |
| Dimension(W×H×D) | 330 mm × 688.3 mm × 275 mm |
| Weight | 40.0 kg |
| Cooling | Forced air cooling, replaceable fan |
| Enclosure rating | IP20 |
| Keypad | KPCC‑01, remote extension supported |
| PCB Conformal coating | Class3C2 |
| Operation temp | 0‑50℃ full rating |
FAQ
1.What are the overall width, height and depth dimensions, net weight of the entire machine, and frame model of VFD900CP43A-21?
The
- Frame model: D1 frame
- Net weight of the entire machine: 40.0 kg
- Overall dimensions of the machine (width 330 mm × height 688.3 mm × depth 275 mm)
2.VFD900CP43A-21 8-pump linkage system, a combination of variable-frequency pump and constant-frequency pump, how many constant-frequency backup pumps can it accommodate at most?
Supported. The
- V Quantitative Cycling (Frequency Conversion + AC Switching Mode): The maximum number of total pumps is 4, with 1 frequency conversion pump and up to 3 AC pumps in alternate rotation.
- 8 total pumps operate in a timed cycling mode: All motors only perform frequency conversion start-stop alternation, and do not support the switching between frequency conversion and AC power supply. There is no logic for AC bypass output.
3.The VFD900CP43A-21 model is the factory-installed model with an operation panel. Does it support remote extension?
The
- Factory-installed operation panel: KPCC-01 LCD operation panel
- Remote extension wiring: Supported, with interface as RJ45.
4.Does the VFD900CP43A-21 cooling fan support disassembly and replacement independently?
The Supports disassembly and replacement separately (modular fan assembly), but does not support hot swapping. Replacement requires the entire machine to be powered off, and the power supply must be discharged completely before proceeding.
Looking for Original New Delta VFD900CP43A-21 CP2000 Series Drive 460V 180A 125HP
We supply this VFD900CP43A-21 mainly to system integrators and maintenance teams for replacement and retrofit projects.
Contact US to get a good prices now