Overview
The AB PowerFlex 753 AC Drive 20F11ND065AA0NNNNN – General-purpose economical model, NEMA open cabinet design, three-phase, 380–480V, 37kW (50HP), 50/60Hz V/F open-loop, EMC filter, common-mode choke coil jumper removed. Hardware integrated STO safety torque shutdown circuit. Embedded logic. Air-cooled cooling. With fan aging warning and diagnosis. Dimensions: height 537 mm × width 267 mm × depth 266 mm. Weight: 14.2 kg.
Specification
| Item | Specification |
|---|---|
| Brand | AB |
| Series | PowerFlex 753 General Purpose AC Drive |
| Catalog Number | 20F11ND065AA0NNNNN |
| Frame Size | Frame 4 |
| Input Supply | 3‑Phase 380–480V AC ±10%, 50/60Hz, 6‑Pulse Rectifier with Pre‑charge Circuit |
| Continuous ND Output Current | 65 A |
| ND 110% Overload (1 min) | 71.5 A |
| Continuous HD Output Current | 52 A |
| HD 150% Overload (3 sec) | 78 A |
| Normal Duty Motor Rating | 37 kW / 50 HP |
| Heavy Duty Motor Rating | 30 kW / 40 HP |
| Output Voltage | 0 ~ 480 V 3‑Phase PWM |
| Output Frequency Range | 0 ~ 650 Hz |
| Adjustable Carrier Frequency | 2 kHz ~ 16 kHz |
| Control Modes | V/F Open Loop, Sensorless Vector (SVC), Closed‑Loop Vector (with encoder option card) |
| Supported Motors | Induction Motor, Permanent Magnet Synchronous Motor |
| Encoder Interface | No onboard port, optional encoder card required |
| I/O Signal Level | 24V DC Digital Inputs & Relay Outputs, STO Safe Torque Off hardware circuit |
| EMC Filter | Built‑in standard EMC filter, common mode choke jumper removed |
| Dynamic Brake IGBT | Integrated inside drive |
| Internal Brake Resistor | Not equipped, external resistor required |
| HIM Configuration | Blank cover, no factory HIM keypad |
| PCB Coating | Non‑conformal coated |
| Cooling System | Forced air cooling, replaceable fan assembly, fan life predictive diagnostic |
| Enclosure Rating | IP20 / IP00, NEMA Open Type |
| Operating Temperature | 0 ~ 50 °C full load without derating; derating required above 50 °C |
| Altitude Derating | No derating ≤1000 m altitude |
| Onboard Communication | No built‑in Ethernet; optional EtherNet/IP, DeviceNet, Profibus add‑on cards |
| Built‑in Functions | DeviceLogix embedded logic, PID, multi‑speed, S‑curve ramp, DC braking, fault log, parameter copy |
| Protections | Overcurrent, Overvoltage, Undervoltage, Module Overtemp, Motor Overload, Ground Fault, Phase Loss, Output Short Circuit, Stall Protection, STO Fault |
| Installation | Side‑by‑side zero stack cabinet mounting |
| Overall Dimensions (W×H×D) | 267 mm × 537 mm × 266 mm |
| Net Weight | 14.2 kg |
| Shipping Weight | Approx. 15.8 kg |
| Product Status | Active / In production |
FAQ
1.20F11ND065AA0NNNNN – Which types of motor control modes does it support?
The
- V/F (volt/hertz) open-loop control
- Speed sensorless vector control (SVC)
- Encoder closed-loop flux vector control (requires an encoder add-on card to be enabled)
- Compatible with both asynchronous induction motors and permanent magnet synchronous motors as load types.
2.What are the overall length, width, depth and net weight of Model 20F11ND065AA0NNNNN?
Supported. The
- Overall machine dimensions (Frame 4, IP20 air-cooled open type, units in mm)
- Width: 222 mm × Height: 474 mm × Depth: 212 mm
- Weight parameters: 13.61 kg
3.What is the working voltage of the 20F11ND065AA0NNNNN terminal, and does it have an STO safety circuit?
The
- IO terminal operating voltage: 24V DC
- Digital input, transistor output, and relay circuit all adopt 24V DC signals. The driver comes with a built-in +24V power terminal for external sensors and switches to obtain power.
- STO safety circuit: Equipped with a hardware-level STO safety torque shutdown circuit.
- Dual-channel hardware STO safety terminals. The two STO signals are mutually checked. Once triggered, the power module output is directly blocked, and the motor torque is cut off, used for emergency stop, safety door, and other safety scenarios.
.
4.What is the protection level of the 20F11ND065AA0NNNNN inverter and the standard of the cabinet?
The
- Protection level: IP20 / IP00
- Cabinet standard: NEMA/UL Open Type (open cabinet)
- It can only be installed inside a sealed control cabinet and must not be exposed directly to water splashes, high dust, or outdoor environments.
Looking for Original New 20F11ND065AA0NNNNN PowerFlex 753 AC Drive 37kW 50HP 65A 480V
We supply this 20F11ND065AA0NNNNN mainly to system integrators and maintenance teams for replacement and retrofit projects.
Contact US to get a good prices now


Reviews
There are no reviews yet.