Product Introduce
20F1AND125AN0NNNNN is a three-phase AC drive of the PowerFlex 753 series, 380–480VAC input, 125A output, regular load 100HP (75kW), heavy load 75HP, air-cooled open IP00/IP20,
Parameter
| Characters | Description |
|---|---|
| 20 | Product Family: PowerFlex 750 Series AC Drives (includes 753/755 sub-series) |
| F | Sub-series & Voltage Class: PowerFlex 753 Series (general-purpose), 380-480VAC 3-phase input (400V class) |
| 1 | Frame Size/Hardware Version: Frame code for 753 Series, matches 125A output rating |
| AND | Core Configuration Package:
– A = Input Side: Built-in EMC filter (enable by disconnecting CM jumper, no input reactor) – N = Control Interface: Standard basic I/O (digital + analog), no additional communication modules – D = Operator Panel (HIM): No built-in/standard HIM (order separately with mounting kit) |
| 125 | Rated Output Current: 125 Amperes (A) |
| A | Voltage/Frequency Standard: 480VAC 50/60Hz (compatible with 380-480V) |
| N | Braking Unit Configuration: No built-in braking transistor (external unit required for braking function) |
| 0 | Safety Function Configuration: No standard safety functions (e.g., Safe Torque Off) |
| NNNN | Extended Options/Custom Configuration: No additional expansion options (e.g., I/O card, communication card, encoder interface card) |
FAQ:
1.20F1AND125AN0NNNNN What is the suitable motor power range under normal load and heavy load conditions?
20F1AND125AN0NNNNN Motor power range adapted to the inverter:
Under normal load conditions: 100HP (75kW)
Under heavy load conditions: 75HP (55kW)
2.20F1AND125AN0NNNNN Can an operation panel (HIM) be installed? If so, which HIM models are compatible?
- Local installation (NEMA 1, drive panel): 20‑HIM‑A6 (enhanced with full numeric keypad), 20‑HIM‑A3/A5 (basic).
- Remote installation (NEMA 4X/12 with cable): 20‑HIM‑C6S (enhanced), 20‑HIM‑C3S/C5S (basic), requires 20‑HIM‑B1 mounting frame and 1202‑C30 cable.
- Accessories: mounting frame 20‑HIM‑B1, connection cable 20‑HIM‑H10 (1m) or 1202‑C30 (3m).
- Tip: 20‑HIM‑A6/C6S is an enhanced model that supports more new functions; the old basic model has limited functions and needs to match the firmware version.
3.From the input side configuration (filter/reactor), what is the core difference between 20F1AND125AN0NNNNN and 20F1AGD125AN0NNNNN?
| Part Number | Input Filter | Input Reactor | Configuration Description |
|---|---|---|---|
| 20F1AND125AN0NNNNN | Built-in EMC input filter (CM jumper disconnect required) | No built-in, external connection needed | Standard filtering configuration for general EMC scenarios |
| 20F1AGD125AN0NNNNN | No built-in EMC filter | Built-in input reactor | Focuses on suppressing grid harmonics and surges, enhancing anti-interference capability |
PowerFlex Air Cooled 753 AC Drive Part Number
20F1AND125JN0NNNNN — PowerFlex Air Cooled 753 AC Drive
20F1ANE125JN0NNNNN — PowerFlex Air Cooled 753 AC Drive
20F14ND125JN0NNNNN — PowerFlex Air Cooled 753 AC Drive
20F1AND125JA0NNNNN — PowerFlex Air Cooled 753 AC Drive
20F1AGD125JN0NNNNN — PowerFlex Air Cooled 753 AC Drive
20F1AND125AA0NNNNN — PowerFlex Air Cooled 753 AC Drive
20F14ND125AN0NNNNN — PowerFlex Air Cooled 753 AC Drive
20F1ANE125AN0NNNNN — PowerFlex Air Cooled 753 AC Drive
20F1AGD125AN0NNNNN — PowerFlex Air Cooled 753 AC Drive
20F14NE125AN0NNNNN — PowerFlex Air Cooled 753 AC Drive
20F14GD125AN0NNNNN — PowerFlex Air Cooled 753 AC Drive
20F14ND125AA0NNNNN — PowerFlex Air Cooled 753 AC Drive
20F1AGD125AA0NNNNN — PowerFlex Air Cooled 753 AC Drive
20F1AND186AN0NNNNN — PowerFlex Air Cooled 753 AC Drive
20F1ANE125AA0NNNNN — PowerFlex Air Cooled 753 AC Drive
20F1AND156AN0NNNNN — PowerFlex Air Cooled 753 AC Drive
20F1AND415AN0NNNNN — PowerFlex Air Cooled 753 AC Drive


Reviews
There are no reviews yet.